Herunterladen Inhalt Inhalt Diese Seite drucken

Function Of The Buttons; Reference Run - Amann Girrbach ceramill motion 2 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für ceramill motion 2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6.4

Function of the Buttons

A
Fig. 23 Buttons
Button
Door shut
Operation
Starts or stops the
button [A]

reference run;

starts or stops the
current program;
activates or deac-
tivates the control
position; activates
the change posi-
tion for the blank
holder
Service but-
interrupts the cur-
ton [B]
rent program; acti-
vates the service
position; activates
the tool-changing
position; activates
a cleaning run of
the inspection win-
dow
Tab. 3
Instead of with the buttons, these func-
tions can also be actuated via the software
(see instructions of the Ceramill Motion 2
software).
A P P L I C A T I O N A N D O P E R A T I O N
B
Door open
activates or
deactivates
the extrac-
tion system
activates or
deactivates
the sealing
air
6.5
Reference Run
After switching on, a reference run must be car-
ried out to determine the mechanical zero points.
Operation button [A] flashes.
To start the reference run:
▷ Briefly press operation button [A].
The reference run is started. Operation button
[A] lights up.
The reference run can be interrupted:
▷ Briefly press operation button [A].
The reference run is stopped. Operation button
[A] flashes.
To continue the reference run:
▷ Briefly press operation button [A].
The reference run is continued at the position
where it was stopped. Operation button [A]
lights up.
On completion of the reference run, the machine
returns to the starting position. Operation button
[A] goes out.
E N
71

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ceramill coolstream

Inhaltsverzeichnis