Herunterladen Inhalt Inhalt Diese Seite drucken

Graphic Symbol Used; Preliminary Instructions; General Description; Basic Version Controller - gefran 1200 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 1200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 82
To distinguish between the type and importance of the information provided in these instructions for use, graphic
symbols have been used as a reference to make interpreting the information clearer.
Indicates the contents of the various manual sections,
the general warnings, notes, and other points to
which the reader's attention should be drawn.
Indicates a particularly delicate situation that
could affect the safety and correct working
operation of the controller, or a rule that must be
strictly observed to avoid dangerous situations
Indicates a condition of risk for the safety of the
user, due to the presence of dangerous voltages
at the points shown
Indicates a suggestion based on the experience
of the GEFRAN Technical Staff, which could
prove especially useful under given
circumstances
This section contains information and warnings
of a general nature which should be read befo-
re proceeding with controller installation,
configuration and use.

General Description

GEFRAN series 1200 / 1300 digital controllers have
been designed for temperature control in any
applications involving heating or cooling processes.
They represent an exclusive combination of
performance, reliability and applicational flexibility. In
particular, this new line of Gefran temperature
controllers is the ideal solution for application in sectors
where performance and service continuity are
important, including:
extrusion lines
injection molding for plastic materials
thermoformers
presses for rubber
wrapping and packaging machines
processing plant for the food industry
cooling switchboards
climatic chambers and test benches
ovens
paint plants
etc.
Graphic symbols used
1 • PRELIMINARY INSTRUCTIONS
The 1200/1300 series temperature controllers are made
on an extremely versatile hardware and software
platform, that allows the most suitable I/O composition
for the plant to be chosen from a series of options, up to
a maximum of:

Basic Version Controller

Options

43
Indicates a reference to Detailed Technical
Documents available on the GEFRAN web
site www.gefran.com
In the programming and configuration flows
AL.1
for the controller, indicates the typical
parameters of the "Easy" configuration, i.e.
the minimum controller configuration
optimized for the basic version that uses
just 2 outputs (OUT1 , OUT2)
In the programming and configuration flows
AL.2
for the controller, indicates all the
parameters that can be set in the
"Extended" configuration.
4 outputs
3 inputs (2 of which are auxiliary)
1 RS485 interface.
1 universal input for TC, 2/3 wire RTD, PTC, NTC,
and linear thermocouples, supplied with current and
voltage with accuracy better than 0.2% f.s.
2 standard outputs: one relay and the other
relay/logic/triac (depending on request)
functions heat/cool, self tuning, autotuning, soft start
alarm for interrupted load or short-circuited probe
service serial line for configuration by PC (Winstrum)
3rd output retransmission relay/
logic/continuous/analogue
4th output relay/logic
2 auxiliary digital inputs with configurable function,
or 1 auxiliary digital input + current transformer input