B.2. ALTERNATIVE FILE LOADING METHOD
Application programs and tables "Exported" (see par. 4.2.8) from EasyGen™ can be
sent to the Formula terminal using a serial port under a different operating system
than Windows 95/98/2000/ME or NT.
Loading an application program
To load the application program in a Formula terminal, in which the interpreter is
already loaded, you must use the default protocol with the serial port set to 9600
baud, 8 bits and MARK parity.
The data or command of the "communication frame" (see Appendix C) must be input
as a single line [without the terminating characters CR(0D Hex) and LF(0A Hex)], of
the file to be sent maintaining the following FIXED sequence:
Appl.CFG file:
1.
table1.INP file:
2.
table1.DAT file: this is a "data" table with the format defined in table1.INP. This
3.
2N - 3N. tableN.INP
appl.CMD file:
4.
For your convenience "Export" also creates an appl.EXP file which is the list without
the table.DAT files required by your application.
104
contains the configuration parameters of the Formula terminal;
contains the first table definition;
file must be created outside EasyGen following the rules
described in par. 4.6.1.
The single text "data" line, without the terminating characters
CR(0D Hex) and LF(0A Hex) preceded by ESC(1B Hex),
"2"(32Hex) and followed by ESC(1BHex), becomes the
"communication frame" (see Appendix C) to be sent.
If your application does not require this file go to step 4.
Repeat step 2 and 3 for every table defined.
contains the actual application program.
EASYGEN™