Mounting

The inclination sensor is fastened to the mounting fixture by means of M5 x L
screws (conforming to DIN 7500 or DIN 7984) for levelling and detection.
To obtain precise measured values avoid mounting onto fixtures which vibrate
much and ensure a sufficient vibration decoupling if this is necessary.
For mounting observe the correct alignment of the inclination axes (see
label on housing) and the notes for parameter setting and alignment of the
sensor (see page 37).
Longitudinal inclination = X axis (Trans PDO 1/2)
Lateral inclination
+15°
longitudinal inclination
The indicated signs of the angle of inclination correspond to the factory default setting.

Electrical connection

2
5
3
8
7
View on pin side
To protect the whole system (wiring and sensor) the supply voltage must be
protected with max. 8 A.
Connecting with 8-wire ifm sockets see page 46.
= Y axis (Trans PDO 2/3)
mounting
X
-15°
4
1
6
surface
+15°
lateral inclination
Description
Operating voltage
CAN interface
Analogue outputs
(X-/Y-axis)
CR2102
INCLINATION SENSOR
Y
-15°
Pin
Potential
1
10...30 V DC
2
GND
3
CAN_H
4
CAN_L
5
CAN_GND
6
I_OUT X
7
I_OUT Y
8
GND_A