Mounting

The inclination sensor is fastened to the mounting fixture by means of 4 M5xL
screws (conforming to DIN 7500 or DIN 7984) for levelling and detection.
To obtain precise measured values avoid mounting onto fixtures which vibrate
much and ensure a sufficient vibration decoupling if this is necessary.
When mounting ensure correct alignment of the inclination axes
(see housing imprint).
Longitudinal inclination = X axis (Trans PDO 1)
Transverse inclination
+15°
longitudinal inclination
The indicated signs of the angle of inclination correspond to the factory default setting.

Electrical connection

4
3
5
1
2
Before commissioning the pins indicated above must be connected to the respec-
tive potentials.
To protect the whole system (wiring and sensor) the supply voltage must be
protected with max. 8 A.
To guarantee the electrical interference protection of the controller, the
housing must be connected to GND (e.g. to the ground of the vehicle).
In addition, the connection cable must be screened.
= Y axis (Trans PDO 2)
mounting
X
-15°
Designation
Operating voltage
CAN interface
surface
+15°
transverse inclination
Pin
Potential
1
GND
2
10...30 V DC
3
CAN_GND
4
CAN_H
5
CAN_L
CR2101
INCLINATION SENSOR