Settings at the switching cabinet
1 Main switch
2 Temperature controller
3 Switch for continuous operations/ coin
verifier
4 Freeze protection switch/ On
Main switch
Position 0: Unit has been switched off.
Frost proteciton is active
Position 1: Unit is ready-to-use.
Temperature controller
The water temperature is set at the thermo-
stat.
30...50 °C for slight dirt.
50...60 °C for cleaning machines and
cars.
The maximum permissible water tempera-
ture for SB operations is 60 °C. (See Tech-
nical Data for maximum possible water
temperature.)
Switch for continuous operations/ coin
verifier
A Continuous operation position: Plant
functions without throwing in coin.
B Coin verifier position: Plant functions
only when coins are thrown in.
Switch On/ freeze protect
A Freeze protect position: Plant is not
ready for use; freeze protect has been
activated. Indicator lamp for operational
readiness does not light up.
B Position On: Unit is ready-to-use. Indi-
cator lamp for operational readiness
lights up.
Caution
The frost protection equipment functions
only when the main switch is at Position 1.
Settings in the switching cabinet
(only for ABS Münzprüfer)
The washing time for each coin that is
thrown in can be set between 1 and 10 min-
utes at the time relay.
1 Time relay
 Turn the main switch to position "0"
 Remove the cover of the switching cab-
inet.
 Set the time relay to the desired period.
 Replace the lid of the switching cabinet.
Settings at the detergent dosing
valve
The dosing valve is used for adjusting the
detergent quantity that is added.
Dosing can be set from 0 to 6% of deter-
gent. The scale on the dosing valve gives
an approximate value. Exact dosing de-
pends on the viscosity of the detergent
used and the ambient temperature. Deter-
mine the exact values by measuring the
amount of detergent that has been sucked
in. Regulate accordingly for lower ambient
temperatures.

Filling in detergents

1 RM 110
2 Detergent
3 Fuel
Pouring in detergent
Danger!
There is a danger because of dangerous to
your health materials. All Kärcher cleaning
agents to contain safety, and application
notices. Notices concerning the application
must be read and obeyed. There listed pro-
tection clothing/protection kit must be wear.
Follow the safety instructions for using de-
tergents.
Caution
If the tank of the cleaning agent is empty,
the high pressure pump will suck air, and
can be damaged. Check the detergent tank
at regular intervals. The filters must be at
the bottom of the detergent tank.
 Open detergent can.
 Mix the detergent with water according
to the details provided on the can.
 Refill detergent or replace the container
with a full container.
 Close the detergent container.
3
-
EN
Deaerating the vacuum pipe for the
cleaning agent
When you want to completely clean the
cleaning agent container or to commission
the appliance for the first time, it is neces-
sary to first deaerate the suction pipe:
 Set the washing programme with deter-
gent (at the programme selection
switch).
 Turn the detergent dosing valve to max-
imum dose.
 Start the high pressure pump by open-
ing the hand spray gun and wait until
the vacuum pipe is free of air bubbles.
 Close the hand spray gun.
 Turn back the dosage valve to the initial
value.
Refill fuel (only for HDS-C 7/11 and
HDS-C 9/15)
Danger
Risk of fire. Follow local regulations for
handling fuels.
Caution
If the fuel tank is empty, the fuel pump runs
dry; this can damage the pump. Check the
fuel tank regularly.
 Open the fuel tank.
 Fill in the fuel (see technical specifica-
tions).
 Close the fuel tank.
Refilling the softener
Caution
Absence of a softener liquid can lead to the
formation of calcium deposits in the plant
and disrupt its functioning. Check regularly
the filling level in the container for softener
liquid.
 Open the container for softener liquid.
 Fill in RM 110.
 Close container.
Coin counter (optional)
The coin counter is located above the coin
verifier inside the plant. It displays the
number of coins that have been thrown in.
To reset, press the button below the dis-
play.

Frost protection

Caution
Risk of damage if there is frosting. Only the
insides of the plant are protected against
frosting. If there is risk of frosting, unscrew
the high pressure hose along with the
hand-spray gun and store it at a frost-free
location. The plant cannot be operated un-
der frost conditions.
The anit freeze equipment contains:
Thermal insulation
Hot air blower
Warning
Danger of injury by freezing. By freezing
shuts down the equipment, in order to
avoid danger of injury.
19