Herunterladen Inhalt Inhalt Diese Seite drucken

Filling In Detergents; Frost Protection - Kärcher SB-Wash-E 10 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Settings at the base exchanger
(optional)
Setting the clock
If teh softening capacity of the base ex-
changer has reduced to 20% it is neces-
sary to do a regeneration.
1 Indicator lamp RM110/Anti Calc System
To ensure smooth daily operations and
avoid calcification of the plant to the maxi-
mum extent possible, a regeneration is
done in the operating breaks in the follow-
ing night from 2.00 hours. For this purpose,
the clock in the head of the base exchanger
must be set to the current time.
For setting the clock:
 Remove the lid of the base exchanger
head.
1 Time switch dial of base exchanger
2 Programme pointer
 Pull out the dial and turn it to the current
time.
 Replace the lid.
Note
To allow regeneration to take place at
night, ensure that the operating type switch
at the operating panel is not set to "0/OFF".
Hence, during operating breaks set the
frost protection to frost protection.
If there is an interruption in power supply
(power failure, main emergency stop switch
set to"'0"), the clock in the control head of
the base exchanger stops and needs to be
reset. Otherwise the time for automatic re-
generation will be postponed.
Manual regeneration
Manual regeneration is triggered by the op-
erator/ Customer Service in cases of:
Start-up of the plant,
inadequate regeneration on account of
lack of salt in the salt tank.
Start regeneration:
 Press red program pointer at the control
head and turn it in the direction of the
arrow towards "START". The control
light at the operation panel RM 110/
Anti Calc System will blink.
26

Filling in detergents

1 RM 110 (Option)
2 CHEM 3 (Option)
3 CHEM 1
4 CHEM 2
5 Salt tank base exchanger (optional)
Pouring in detergent
Caution
If the tank of the cleaning agent is empty,
the high pressure pump will suck air, and
can be damaged. Check the detergent tank
at regular intervals. The filters must be at
the bottom of the detergent tank.
CHEM 1
High pressure cleaning, brush
cleaning
CHEM 2
Conservation
CHEM 3
(Option) Alloy wheel
Danger!
There is a danger because of dangerous to
your health materials. All Kärcher cleaning
agents to contain safety, and application
notices. Notices concerning the application
must be read and obeyed. There listed pro-
tection clothing/protection kit must be wear.
 Open the cleaning agent tank.
 Pour in the cleaning agent, or exchange
the tank by a full tank.
 Close the cleaning agent tank.
Deaerating the vacuum pipe for the
cleaning agent
When you want to completely clean the
cleaning agent container or to commission
the appliance for the first time, it is neces-
sary to first deaerate the suction pipe:
 Set the washing programme using the
cleaning agent whose vacuum pipe
needs to be deaerated (at the pro-
gramme selection switch)
 Turn the rotary knob of the respective
dosing pump to position 10.
1 Deaeration valve
2 Deaeration hose
 Hold the deaeration hose over a drain-
age.
5
-
EN
Warning!
Risk of injury on account of any concentrat-
ed detergent coming out of the hose. Do
not direct the hose on persons or animals.
 Open the deaeration valve.
 Start the high pressure pump by open-
ing the hand spray gun and wait until
the vacuum pipe is free of air bubbles.
 After deaerating the last detergent vac-
uum pipe: Set programme to 'rinsing' at
the programme selection switch and let
it run for 5 seconds.
 Close the hand spray gun.
 Close deaeration valve.
 Roll up the deaeration hose and hang it
above the deaeration valve.
 Turn back the dosage pump to the initial
value.
Fill in water softening agent
(Option)
Caution
Risk of functional disturbances. While filling
the softening salts, use only the softening
salt in the tablet form listed in the chapter
"Accessories".
 Open the salt tank.
 Fill up softening salt up to a level above the
water level; better: just fill it to the top.
 Close the salt tank.
Fill in water softening agent
(Option)
Caution
Absence of a softener liquid can lead to the
formation of calcium deposits in the plant
and disrupt its functioning. Check regularly
the filling level in the container for softener
liquid.
 Open the container for softener liquid.
 Fill in RM 110.
 Close the container.

Frost protection

Notice
Equipments without anti freeze may not be
operated during a time of frost.
The anit freeze equipment contains:
Heat insulation
fan heater
Anit freeze cycle cleaning tool
outside thermostat (optional)
Notice
By integrated anit freeze equipments, the
following features are guaranteed.
Unlimited washing operation up to -
5gard C.
Reduced washing operation below -5
grad C. By the reduced washing opera-
tion, the brushed must be check of
freezing regularly. If washing with a fro-
zen brush, the vehicle might get dam-
aged. By frozen brushes, the combi- jet
must be exchanged by the high pres-
sure jet. If you wish to extent the opera-
tion to lower temperature, please
contact your local service agent. At –15

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sb-wash-e 5

Inhaltsverzeichnis