Technical data
Condensation
Measuring category
Pollution degree
Design, dimensions
Weight
98
Surge
Conducted RF
Permitted
Measuring category II as per IEC 61010-1. The measuring category is provided for measurements
at circuits with a direct electrical connection to the low voltage supply.
Pollution degree 2 as per IEC 61010-1
10.0.6

Mechanical construction

Fig. 11:
Data in inches (mm)
Die-cast aluminum housing for general purpose or as option stainless steel housing
*dimensions without display = 112 mm (4.41 in)
Fig. 12:
Data in inches (mm)
Optional T17 stainless steel housing for hygienic applications
• Separate electronics compartment and connection compartment
• Display rotatable in 90° stages
• Approx. 1.4 kg (3 lbs), with display, aluminum housing
• Approx. 4.2 kg (9.3 lbs), with display, stainless steel housing
• Approx. 1.25 kg (2.76 lbs), with display, T17 housing
IEC 61000-4-5
0.5 kV sym.
IEC 61000-4-6
0.01 to 80 MHz
TMT162
10 V
T09-TMT162ZZ-06-00-xx-ae-001
T09-TMT162ZZ-06-00-xx-ae-003
Endress+Hauser