10 Technical Data
Influence of ambient
temperature (temperature
drift)
Long term stability
Influence of reference junction
Installation hints
Ambient temperature
Storage temperature
Climatic class
Condensation
Ingress protection
Impact and vibration protec-
tion
Electromagnetic compatibility
(EMC)
Dimensions
Weight
80
Voltage transmitter (mV)
Resistance thermometer (RTD): T
Resistance thermometer Pt100: T
= ± 50 ppm/K * max. Measurement range * ∆ ϑ
Thermocouple (TC): T
d
∆ ϑ = Deviation of ambient temperature from the reference conditions.
1
≤ 0.1K/year
Pt100 DIN IEC 751 Kl. B (internal reference junction for thermocouples TC)
10.0.6
Application conditions (installation conditions)
• Installation angle: No limitations
• Installation area: Connection head according to DIN 43 729 Form B; Field housing TAF 10
10.0.7
Application conditions (ambient conditions)
−40 to +85 °C (for hazardous areas see Ex certification)
-40 to +100 °C
according to IEC 60654-1, Class C
allowable
IP 00, IP 66 installed
4g / 2 to 150 Hz according to IEC 60068-2-6
Interference immunity and emission according to IEC 61326 and NAMUR NE 21
10.0.8
Mechanical construction
Fig. 10.1: Head transmitter dimensions in mm
approx. 50 g
1. Under reference conditions
± 20 µV
= ± 15 ppm/K * max. Measurement range * ∆ ϑ
d
= ± 15 ppm/K * (Measurement range end value +200) * ∆ ϑ
d
TMT184
-10 to 75 mV
Endress+Hauser