Operation
Measured
PV
values
Standard
Matrix
Function
parameter
set-up
mode
Sensor type
Sensor 1
Sensor 1
Sensor type
Sensor 2
Sensor 2
Output
PV up
range value
Safety
Reaction
settings
S1 <> S2
Display
Display
Diagnosis
Device status
Identification
Measuring
point
Service
Security
locking
functions
72
PV value
Value
Value
AO
in %
Sensor 1
Sensor 2
Min measurm
PV mode
PV unit
range
2-wire
Cold
External
Sensor
comp. S1
connect. S1
junction S1
temp. S1
2-wire
Sensor
Cold
External
connect. S2
comp. S2
junction S2
temp. S2
PV lo
Analog
HART
Filter time
range value
output
Output mode
Fault
Alarm
Corros.
Ambient
condition
hysteresis
detection
alert
Decimal
Display
Display text
places
interval
Status
Status
Config.
Last
Sensor 1
Sensor 2
changed
diagnostic
Device infos
Tag
Descriptor
Message
Simulation
Simulation
Trim
Default
mode
value
4 mA
values
The black highlighted function fields
are marking the Quick Setup menu.
®
Fig. 10:
HART
function matrix
5.3.2
FieldCare
FieldCare is a universally applicable service and configuration software based on FDT/DTM
technology. Connection is established by means of a HART
Detailed information is provided in the installation instructions of the FieldCare configuration
software (see chapter 'Documentation'). The DTMs available for the device also allow operation by
means of operating programs of other manufacturers that support FDT/DTM technology.
5.3.3
ReadWin
®
ReadWin
2000 is a universally applicable service and configuration software. Connection is made
®
using a HART
modem, e.g. Commubox FXA191. The operating software offers the user the
following possibilities:
• Setup device functions
• Measured value visualization
• Device parameter data storage
• Measuring point documentation
NOTICE
Analog output
► The analog output is undefined when downloading the device function parameters from
®
ReadWin
2000 to the device.
Further in-depth information on operation via ReadWin
documentation of the software. ReadWin
following address:
www.endress.com/Readwin
RJ value
Max
RTD
measurm
connection
range
Offset
Meas. unit
Value
sensor1
sensor1
sensor1
Offset
Meas. unit
Value
sensor2
sensor2
sensor2
Num. resp.
Poll
preams
addr.
Over-/Under-
Mains filter
range alarm
Min. value S1
Max. value S2
Max. value S1
E+H Device
E+H Soft-
E+H serial no.
release
ware rev.
Trim
20 mA
®
2000
®
2000 can be downloaded free of charge from the
Serial no.
S1
Serial no.
S2
Max.
Min.
Min. value S2
RJ value
RJ value
Certificates
Manufacturer
Model
Date
®
modem, e.g. Commubox FXA191.
®
2000 can be found in the online
TMT162