Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser iTEMP HART TMT162 Bedienungsanleitung Seite 81

Vorschau ausblenden Andere Handbücher für iTEMP HART TMT162:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TMT162
®
Available in ReadWin
2000, HART
Commuwin II with Matrix address
Diagnostics
• Static revision
The "Static revision" is increased on every parameter change. This is for
compliance to 21 CFR Part 11, showing that no further parameter changes
have been made.
• Sensor 1 max. value
• Sensor 1 min. value
• Sensor 2 max. value
• Sensor 2 min. value
• RJ max. value
• RJ min. value
Display of the maximum process value. The process value will be accepted after
starting the measurement.
Display of the minimum process value. The process value will be accepted after
starting the measurement.
Display of the maximum and minimum measured temperatures of the internal
Pt100 DIN B comparison measurement point.
• Maximum process value is changed to the actual process value on write
access. On reset to factory default value the default value is entered -10000.
• Minimum process value is changed to the actual process value on write access.
On reset to factory default value the default value is entered +10000.
®
Available in ReadWin
2000, HART
Commuwin II with Matrix address
Measuring point
Input and display of the information relating to the measuring point identification
Measuring
Input: 8 characters
point TAG
Description
Input: 16 characters
Message
Input: 32 characters
Device information
Display of the information relating to the device identification
Commuwin
Special Commuwin device version, e.g.: 8010 means Version 1.0
device version
Device release
Display of device release
Serial number
11 digit display of the Endress+Hauser device serial number
(equal to that on the legend plate).
Software
Display of the software version
version
Hardware
Display of the hardware version
version
Certificates
Display of device approvals
Device
Display of the information relating to the HART
Endress+Hauser
Function group DIAGNOSTICS
®
handheld module DXR275/375 (Symbol
Function group IDENTIFICATION
®
handheld module DXR275/375 (Symbol
®
device identification
7
®
),
ReadWin
2000
-
+
+
+
+
+
+
7
®
),
ReadWin
2000
+
+
-
-
-
+
+
+
-
Commissioning
7
/FieldCare
CW II-
Matrix
-
• V9H3
+
• V8H0
+
• V8H1
+
• V8H2
+
• V8H3
+
• V8H4
+
• V8H5
7
/FieldCare
CW II-
Matrix
+
VAH0
+
VAH1
+
-
VAH3
+
VAH2
+
VAH4
+
VAH6
+
VAH7
+
81

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis