EVCO S.p.A.
User interface-control module communication error.
To correct
BOARD
COMMUNICATIO
-
NS
Main consequences
-
User interface-control module compatibility error.
To correct
BOARD
-
COMPATIBILITY
Main consequences
-
Needle probe alarm (all the needle probe sensors enabled are in alarm status)
To correct
NEEDLE PROBE
-
Main consequences
-
Power failure alarm (HACCP alarm).
To correct
-
POWER FAILURE
Main consequences:
-
-
-
Sanitation alarm.
To correct
SANITATION
-
PROBE
INSERTION
Main consequences
-
Alarm indicating that sanitation has not been completed within the maximum duration (HACCP
alarm).
To correct
-
SANITATION
DURATION
Main consequences
-
-
-
Condenser overheat alarm.
To correct
-
CONDENSER
-
OVERHEAT
Main consequences
-
-
Vcolor 869/879 | Installer manual ver. 4.0 | Code 144VC869E404
Check the user interface-control module connection.
Any cycle underway will be terminated and it will not be possible to start one up.
Check that the user interface and the control module are compatible.
Any cycle underway will be terminated and it will not be possible to start one up.
The same as for the cabinet probe error but with reference to all the needle probes.
Any temperature controlled cycle will be interrupted
Check the device-power supply connection.
The device will memorise the alarm.
Any cycle underway will resume when power is restored.
The alarm output will be activated.
Check that the needle probe has been correctly inserted and check the value of
parameters r17 and r18.
The sanitation cycle will be interrupted.
Check the value of parameter r23
The device will memorise the alarm.
The cycle underway will be interrupted.
The alarm output will be activated.
Check the condenser temperature.
Check the value of parameter C6.
The condenser fan will be switched on.
The alarm output will be activated.