Tefcold BLC3AX1 Benutzerhandbuch Seite 267

Schockfroster /gefrierschrank
Inhaltsverzeichnis
EVCO S.p.A.
Condenser probe error.
To correct
-
Main consequences
CONDENSER
PROBE
-
-
-
-
Needle probe/sensor 1 error.
To correct
-
Main consequences if parameter P3 is set to 1 (single probe)
-
-
NEEDLE PROBE
SENSOR 1
-
-
-
Main consequences if parameter P3 is set to 2 or 3 (multineedle or multi-sensor probes)
-
Needle probe/sensor 2 error.
To correct
NEEDLE PROBE
-
SENSOR 2
Main consequences
-
Needle probe/sensor 3 error.
To correct
NEEDLE PROBE
-
SENSOR 3
Main consequences
-
Thermal switch alarm
To correct
-
THERMAL
-
SWITCH
Main consequences
-
-
Vcolor 869/879 | Installer manual ver. 4.0 | Code 144VC869E404
The same as for the cabinet probe error but with reference to the condenser probe.
The condenser fan will operate in parallel with the compressor.
The condenser overheat alarm will never be activated.
The compressor locked alarm will never be activated.
The alarm output will be activated.
The same as for the cabinet probe error but with reference to needle probe 1.
If the error happens during stand-by, the temperature controlled cycles will be started
up as time-controlled.
If the error happens during temperature controlled blast chilling, blast chilling will last
for the time set by parameter r1
If the error happens during temperature controlled blast-freezing, blast-freezing will last
for the time set by parameter r2
If the error happens during needle probe heating, the heating will be interrupted.
The alarm output will be activated.
The device will not use the probe/sensor showing the error but the other available probes
or sensors will be used.
The same as for the cabinet probe error but with reference to needle probe 2.
The device will not use needle probe 2.
The same as for the cabinet probe error but with reference to needle probe 3.
The device will not use needle probe 3.
Check the state of the thermal switch input.
Check the value of parameter i11.
The cycle in progress will be interrupted
The alarm output will be activated.