EVCO S.p.A.
7.1.1 Combined cycle with slow cooking
When setting a manual blast chilling/freezing cycle, if available in the machine configuration a slow cooking cycle can be
added after a blast chilling/freezing. In the lower part of the screen, two dedicated areas make it possible to add a slow
cooking phase
or a slow cooking + holding phase.
For slow cooking or slow cooking + holding the pre-settings are those of the standard cycles.
When setting a manual cycle, the values of each phase can be edited any time.
Below is an example for setting a hard blast chilling+ slow cooking + holding.
7.2
Hard blast chilling/soft blast-freezing and conservation
It is possible to select a hard blast chilling/soft blast-freezing cycle on the blast chilling/blast-freezing settings screen by
pressing area
or
has been set.
This cycle consists of two blast chilling phases at different set points, followed by a conservation phase.
-
The first phase, known as hard for blast chilling and soft for blast-freezing, has set points established by
the relevant parameters and these cannot be modified;
-
The set points for the second blast chilling/blast-freezing phase can be modified;
-
The set points for the third conservation phase can be modified.
Vcolor 869/879 | Installer manual ver. 4.0 | Code 144VC869E404
. Before selecting this mode, make sure the type of cycle (temperature or time controlled)
page 29 of 96
.