Troubleshooting

No image is visible / The user inter-
face cannot be reached.
Check whether all supply lines are correctly con-
nected and the system is supplied with power. For
a connection via HDMI, check whether the moni-
tor is correctly connected and switched on, and if
the correct input source is selected.
The rotor is not spinning
Check whether the device is correctly connect-
ed and switched on. Check whether the rotor can
turn freely and s not blocked. If the motor does not
start up when the system is launched, please con-
tact customer service.
The LED light is not working
Check whether the light is switched on in the user
interface. If only one of the two modules or none
of them is working, please contact customer ser-
vice.
The window fogs up / liquid enters
the intervening area between the
rotor and the cover.
Check whether the sealing air is correctly con-
nected and configured and whether there is an
error message from the system. If the settings
are correct, check the cleanliness of the sealing
air according to the requirements indicated in the
chapter "Technical data" in the appendix. If it is too
dirty, install a service unit to ensure the required
purity of the sealing air.
The image is fuzzy or unclear.
Check whether the inside/outside of the rotor is
dirty and clean it with a damp cloth. If necessary,
use a suitable cleaning agent such as glass clean-
er or isopropyl alcohol. Also measure the working
distance of the camera head and check whether
it corresponds to the focus position of the lens. If
the camera head is operated at an incorrect dis-
tance, no clear image can be displayed. The focus
position can only be changed by the manufactur-
er because it is sealed to keep out media, partic-
ularly if the rotor fails due to damage from broken
tool or workpiece parts. Either change the work-
ing distance or procure a camera head that has
the right focus.
The stream has image interferences.
Check whether your data cables are laid such that
there are no interfering signals, e.g. from power
cables. Use only the data cable provided. Do not
extend the data cables, as every interface im-
pacts quality and reduces the maximum possible
data cable length