Operating current (max.)
Polytron 5100 EC
without relay, non-
remote sensor
with relay, remote
sensor
Polytron 5200 CAT
without relay, non-
remote sensor
with relay, remote
sensor
Polytron 5310 IR
without relay, non-
remote sensor
with relay, remote
sensor
Polytron 57x0 IR
without relay, non-
remote sensor
with relay, remote
sensor
Operating currents are valid for 24 V
17.5 General specifications
Enclosure Polytron 5xx0
Enclosure material
Enclosure protection NEMA 4X
Display
1) Polytron 5100 EC has no NEMA 4X enclosure protection
17.6 Environmental parameters
See sensor data sheet for sensor specifications and
influences.
Polytron 5xx0
Pressure
Humidity
Temperature
1)
Polytron 5100 EC
3)
Polytron 5200 CAT
Polytron 5310 IR
3)
Polytron 57x0 IR
Instructions for use
|
Dräger Polytron 5000 Series
80 mA
100 mA
105 mA (DrägerSensor DD / DQ)
130 mA (DrägerSensor LC)
145 mA (DrägerSensor DD / DQ)
165 mA (DrägerSensor LC)
145 mA
185 mA
330 mA
350 mA
.
copper free aluminum or 316
stainless steel
1)
IP 65/66/67
4 digit, 9 segment, back-lit
20.7 to 38.4 in. Hg (700 to
1300 hPa)
0 to 100%RH, non-condensing
-40 to +149 °F (-40 to + 65 °C)
2)
-40 to + 158 °F
(-40 to + 70 °C)
-40 to +176 °F (-40 to +80 °C)
-40 to +149 °F (-40 to +65 °C)
-40 to +170 °F (-40 to +77 °C)
2)
-40 to + 176 °F
(-40 to + 80 °C)
Polytron 5xx0
Storage temperature
Storage pressure
Storage humidity
1) See specific EC sensor data sheet for limitations to the maximum
specification.
2) Value from Ex approval. For values without this footnote, EX and per-
formance Approval values are identical.
3) Except for relay option and UL approval-relevant installations. For
relay option and UL installations: -40 to + 158°F (-40 to +70°C)
The values for accessories and spare parts are less strict than
or identical to those of the transmitter. For exact values, refer
to the corresponding manual.
17.7 Tightening torque
Instrument threads
Enclosure lid
Sensor
Blind plugs
Ports (for conduits or
cable glands)
Instrument to Dock-
ing Station (4
screws)
Field wiring terminals
Power supply, sig-
nals and relays
Grounding screws
18
Accessories and spare parts
This chapter gives an overview of the main parts that are
covered by the BVS 13 ATEX G 001 X type examination. For
other parts refer to the spare parts list or contact
DrägerService.
18.1 Polytron 5xx0
Description
IRDA to PC interface
Magnetic wand with key
chain
Hardware kit enclosure
EXd cable gland for non-con-
2)
duit installations
EXd blind plug stainless steel 45 44 321
EXd blind plug galvanic steel 68 12 269
2)
Relay board
Accessories and spare parts
-4 to +149 °F (-20 to +65 °C)
26.5 to 32.4 in. Hg (900 to 1100
hPa)
0 to 100%RH, non-condensing
62 ±17.7 LB IN. / 7 ±2 Nm
min. 266 LB IN. / min. 30 Nm
min. 266 LB IN. / min. 30 Nm
min. 443 LB IN. / min. 50 Nm
71 LB IN. / 8 Nm
4.4 - 7.0 LB IN. / 0.5 - 0.8 Nm
10.6 LB IN. / 1.2 Nm
Part Number
45 44 197
45 44 101
45 44 167
AG 00 570
45 44 297
|