Herunterladen Diese Seite drucken

Hürner HST 300 Print+ 2.0 Bedienungsanleitung Seite 37

Vorschau ausblenden Andere Handbücher für HST 300 Print+ 2.0:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Press the START/SET key to confirm the set-up and save it to
memory.
10.1 Understanding the "Settings" Sub-menu
"AutoWeld on" means that the AutoWeld feature for the easy defi-
nition of welding parameters (see Sect. 5.5) can be used, "off,"
that the feature is not available.
"Check Code Expiry on" means that the welder identification code has
to be current and not expired (default period of validity 2 years
from code issuance), or the welding operation cannot be started,
"off," that the validity of the code is not checked at all.
"Memory Control on" means that when the system memory is full of
reports, the unit will be blocked until the reports are printed or
downloaded, "off," that it works but that the oldest report will
be overwritten.
"Manual Input on" means that the manual input of welding param-
eters (see Sect. 7) is possible, "off," that the manual input is not
allowed.
"Welder Code Options – M – " means that by pressing the MENU
key, the user can access a sub-menu that allows determining
when the welder code, if it is enabled at "Recording," has to be
entered:always, i. e. before evey single welding operation, only
before the first welding operation after switching the unit on or
only after the first welding operation of a new day/date.
"Language – M – " means that by pressing the MENU key, the user
can access a sub-menu for selecting the display and report lan-
guage (see Sect. 10.1.1).
"Date/Time – M – " means that by pressing the MENU key, the user
can access a sub-menu for setting the clock (see Sect. 10.1.2).
"Buzzer Volume – M – " means that by pressing the MENU key, the
user can access a sub-menu for setting the volume of the status
buzzer (see Sect. 10.1.3).
"Temperature Unit – M – " means that by pressing the MENU key, the
user can access a sub-menu for selecting centigrade or Fahrenheit
as the unit for the temperature.
"Inventory Number – M – " means that by pressing the MENU key,
the user can access a sub-menu for entering the number under
which the unit is inventorized with the operating company.
"Number of Tags – M – " means that by pressing the MENU key, the
user can access a sub-menu for entering the number of tags that
are printed automatically after welding with the optional label
tag printer if such a printer is connected.
10.1.1 Selecting the Display Language
When the "Select Language" sub-menu was selected, the screen
changes and the display reproduced in Display 22 appears.
Use the arrow keys ñ and ò to select one of the options, "Deutsch,"
"English," and "Français" and confirmby pressing the START/SET
key.
10.1.2 Setting the Clock
When the "Set Clock" sub-menu was selected, the screen changes and
the display reproduced in Display 23 appears.
The time of day and the date can be set using the keypad. The portions
"Hour," "Minute," "Day," "Month," and "Year" are set separately.
Press the START/SET key to confirm your settings.
Version August 2014
HÜRNER HST 300 Print + 2.0 User's Manual
***
SET-UP MENU ***
>AutoWeld
on
Check Cd Expiry off
Memory Control
on
Display 18
***
SET-UP MENU ***
Manual Input
-M-
Wldr Code Option-M-
>Language
-M-
Display 19
***
SET-UP MENU ***
Date/Time
-M-
Buzzer Volume
-M-
>Temp. Unit
-M-
Display 20
***
SET-UP MENU ***
>Temp. Unit
-M-
Inventory No.
-M-
Number of Tags
-M-
Display 21
***** LANGUAGE *****
>Deutsch
English
Francais
Display 22
Date/Time
21.06.13
14:28
Display 23
EN