7.1
Manually Entering Welding Voltage and Time
If this option was chosen in the manual parameter input menu, a
display like the one to the right appears on the screen. Use the alpha-
numeric keypad (see Info in Sect. 5.2) to set the welding voltage and
the welding time, according to the fitting manufacturer's instructions,
then press the START/SET key to confirm your input. The "Start ?" mes-
sage displayed after the confirmation by START/SET indicates that the
unit is ready for welding.
7.2
Entering the String of Numbers
If this option was chosen in the manual parameter input menu, the
"Enter Fitting Code" display shows. The 24 characters of the fitting
code to be entered display as asterisks ( * ). Use the alphanumeric
keypad (see Info in Sect. 5.2) to enter the code and press START/SET
to confirm your input and have it decoded. If the code entered is not
correct, a "Code Error" message appears; check the string of numbers
and correct as needed. If the code is correct, the decoded data is dis-
played, and the "Start ?" message indicates that the unit is ready to
start welding.
8
Downloading the Reports
Interface
USB A Interface Port
for connecting USB mass storage media (such as a memory
stick)
The interface port complies with the USB version 2.0 specification (i.e.,
maximum data rate of 480 megabits per second).
Before transferring data, it is highly recommended to switch
the welding unit off and on again. If this fails to happens,
there is a risk of data transfer failure, or reports in the weld-
Important
ing unit may be corrupted.
When transferring welding reports to a USB stick, always
be sure to wait until the display shows the "Download fin-
ished" message before you disconnect the USB stick from
Important
the product. If you disconnect it too early, the unit may ask
you whether you want to delete the reports in memory, al-
though they were not properly transferred. In this case, if
you delete the contents of the report memory, the welding
reports would be irrevocably lost and would not be available
elsewhere either.
8.1
Selecting the File Format
Connecting the storage media causes the the screen to appear in which
the format of the output file with the welding reports can be selected:
a PDF file with an abstracted or extended version of the report or the
format of the welding data management application DataWork. Using
the ñ and ò arrow keys, select the file type you need and confirm
your selection by pressing the START/SET key.
The Service Report option is not important for normal operation. In
the scope of computer-assisted unit service, this report lists the events
related to the maintenance of the welding unit.
14
EN
HÜRNER HST 300 Print + 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Voltage/Time
U= 40 V
* Select File Type *
DataWork File
>PDF Abstract
PDF Ext'd Report
Version August 2014
t=
1000 s
Display 15
Display 16

Werbung

loading