c) Display elements
A Current status / operating mode
B Air flow
C Air flow and temperature for button „1"
D Symbol for air flow setting
E Air flow and temperature for button „2"
F Air flow and temperature for button „3"
G Current preset temperature
H Measured temperature („- - -" is displayed in standby mode)
I Display bar for heating function (more bars indicate a higher heat setting)
J Symbol for activated vacuum suction lifter
d) Manually selecting the air flow and temperature
• Briefly press the "MENU/ENTER" button to switch between the air flow and temperature settings. The program-
mable value will be highlighted in white on the display.
• Use the "
" button to decrease the value and the "
adjust the value more quickly.
Air flow range: 25 - 99%
Temperature range: 100 - 480 °C
In the functions menu you can set an upper and lower limit for the temperature. You can also enable the
temperature lock.
44
" button to increase the value. Hold down the button to