10. Calculate the amplifier gain with the following formulas.
Gain = Output Signal / Input signal
Gain (db) = 20×log (gain)
Example 3: Capture the Single Signal
The digital storage oscilloscope takes the lead in providing the convenience capturing of such non-periodic
signals as pulse and burr, etc. If you intent to capture a single signal, you can not set the trigger level and the
trigger edge unless you have a particular priori knowledge of this signal. For example, if the pulse is the logic
signal of a TTL level, the trigger level should be set to 2 volts and the trigger edge be set as the rising edge
trigger. If it is uncertain as to the signal, you can make an observation of it in advance under the automatic or
ordinary mode to determine the trigger level and the trigger edge.
Fig. 55 Wave Form of Gain Measurement