Care and maintenance

Procedure:
3
2
1
Fig. 35
Establish the power supply via the battery cut-off
switch� Green LED (Fig. 35-2) lit�
Press the reset button (Fig. 35-1) on the remote
control with a thin object� The antenna of the control
unit can be used for this�
The green and red LEDs (Fig. 35-3) on the remote
control now flash alternately�
Then switch on the remote control� To do this, press
the green ON button
The control unit and remote control pair automati-
cally� The green LED on the control unit lights up�
36
EN
7
Care and maintenance
RISK
Severe to lethal injury due to short
circuiting
Parts of the appliance are supplied with power
over an on-board power supply consisting of
12 V batteries� In the event of high electrical
loads or a short circuit, very high currents can
flow through the supply lines, causing the
cables to heat up and a cable fire to break out�
Fuse cables with appropriate safety fuses�
Cover the battery terminals�
Cover open electrical contacts�
Use isolated plug-in connectors�
NOTICE
Damage to the manoeuvring system due to
incorrect cleaning
Do not clean the manoeuvring system with a
high-pressure cleaner�
Only use gentle detergents�
Cleaning and user-performed maintenance must not be
carried out by children when unsupervised�
7.1
12 V battery care
Notes for handling batteries
When handling batteries, pay attention to the
manufacturer's safety instructions and data sheets�
Ensure that the terminal clamps are secure�
Secure battery poles with protection caps in order to
prevent a short circuit
When removing the battery, first disconnect the
earth connection (negative terminal), followed by the
positive terminal�
When installing the battery, first connect the positive
terminal followed by the negative terminal�
Battery care (including maintenance-free batteries)
In order to achieve a long battery service life, attention
must be paid to the following points:
Batteries should be fully charged before and after
removing power�
For stationary periods of longer than 24 hours, inter-
rupt the power circuit (e�g� using the battery cut-off
switch or by disconnecting the battery poles)�
For longer stationary periods the battery must be
disconnected and charged for 24 hours at least eve-
ry 12 weeks�

In winter, store the fully-charged battery in a cool
and frost-free place and recharge at regular intervals
(every 12 weeks)�
7.2

Remote control care

The remote control must be kept in a dry place�
Remove the remote control's batteries during exten-
ded stationary periods (e�g� in winter) to prevent the
batteries from going flat�
GO2 RH3
60040-00325 ∙ 00 ∙ 08/2022

Werbung