Water supply

If a water supply is being installed in the vehicle, it must be
ensured that sufficient room is left between the water hoses
and the heat source (e.g. heater, warm air duct).
A water hose may only be routed at a distance of 1.5 m from
the heater at the warm air duct. The Truma SC hose clip (part
no. 40712-01) can be used with this distance or more. With
parallel routing (e.g. through a wall) a spacer (e.g. insulation)
must be fitted in order to avoid contact.

Other

If a perforated drawer is installed over the heater that is used
for drying objects, for example, an intermediate shelf made
from non-coated wood must be installed (minimum depth
280 mm or 380 mm for S 5004). The covers of the installation
compartment must be made from temperature-resistant ma-
terial (not PVC or the like).
If the vehicle floor is being coated with underfloor protection,
all heater parts located beneath the vehicle must be covered
so that the resulting spray mist does not cause heater sys-
tem malfunctions. Remove covers again when the work is
complete.
In order to achieve even and quick warm air distribution
and to minimise the surface temperatures at the warm
air outlet grille, we recommend installing a Truma TEB-3 or
TN-3 fan. The S 5004 heater must be equipped with at least
one fan. A special installation box is available for operation
with two fans.

Preparation work and installation box

For problem-free operation of the device it is important
for the bottom edges of the installation box and the
heater base to be on the same plane, and the base to be posi-
tioned in accordance with the installation template so that the
control knob is not too high or too low.
Attach the installation template to the floor of the installation
cut-out for the installation box. The arrow must point exactly
to the leading edge of the cut-out (R = right-hand installation,
L = left-hand installation).
Saw out the floor cut-out and prepare the 5 points for the fas-
tening screws.
Seal interfaces and allow them to dry completely. Do not use
any flammable / heat-sensitive materials.
16
Fig. A (right-hand installation) / fig. B (left-hand installation)
Insert the frame halves (4) into the floor cut-out, push out-
wards and screw down (pretension by bending open the legs
beforehand if necessary so that the frame sits properly).
The sealing means that an additional seal between the frame
halves and the floor is not required.
If the vehicle manufacturer stipulates a seal, surplus sealing
material, particularly detached threads, must be removed.
Do not use any flammable / heat-sensitive materials.
Break out the pre-punched breakthrough for the exhaust pipe
on the installation box (1) (R = right-hand installation, L = left-
hand installation). The exhaust pipe of the S 5004 heater can
also be led through from the side if the installation depth is
low (R1 or L1).
S 3004 / S 3004 P
1
T
R
U
L
Fig. 2
If a Truma fan and / or the Truma Ultraheat additional
electric heater is installed, remove the cover (T or U) and
pre-attach this to the installation box in accordance with the
respective enclosed installation instructions.