Technical Information
Connection P1 Logic Input Interconnections

Connection J2 - Logic Output Interconnections

Figure 9
All the logic output from the controller must be connected at P2
mating connector. With the optional P2 mating connector make the
connection with AWG 24 (0.25 mm ) or smaller wire to the pins
indicated in the figure to obtain the desired capability. The following
table describes the signals available on the connector.
Tab. 4
PIN
8-15
1-10
4-12
3-11
2-10
214/274
Logic output connector
DESCRIPTION
Analog output Voltage of DC current drawn by the turbopump (pin 8 positive,
pin 15 negative). 1 Vdc proportional to 2,5 A.
RELAY 1 signal 24 V. 60 mA, optically isolated output (pin 10 positive, pin 1
negative). The output Voltage will be present when the rotational speed of the
pump is higher than the selected high speed threshold.
LOW SPEED signal, 24 V, 60 mA, optically isolated output (pin 12 positive, pin 4
negative). The output Voltage will be present when the low speed mode is
selected either through the front panel the remote signal, or serial port.
START signal 24 V. 60 mA, optically isolated output (pin 11 positive, pin 3
negative).
The output Voltage will be present when the START push-button on front panel
is pressed or the remote start is present. or the function has been requested by
RS 232, until NORMAL operation is reached.
RELAY2 signal 24 V. 60 mA, optically isolated output (pin 10 positive, pin 2
negative).
Turbo-V 6000 Controller User Manual / 87-900-855-01 (F)

Werbung

loading

Diese Anleitung auch für:

969-9491969-9591