Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Description; Description; Technical Data; Standard Equipment - CEMONT MS 2000M Betriebs-Wartungs Und Sicherheitsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
GB

3.0 TECHNICAL DESCRIPTION

3.1

DESCRIPTION

COMPACT RANGE CONTINUOUS WIRE WELDING MACHINES, WITH WIRE
FEED UNIT AND REEL HOLDER SPOOL HOUSED- IN A PROTECTED COMPART-
MENT.
MIG/MAG WELDER SWHICH CAN WELD MILD STEEL, STAINLESS STEEL
AND ALUMINIUM.
OPTIONAL
VERSION FOR CORE WIRE WITHOUT GAS.
3.2

TECHNICAL DATA

DATA PLATE
Single phase supply
Frequency
Effective consuption
Maximum consuption
Open circuit voltage
Welding current
Duty cycle 15%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
Three phase supply
Frequency
Effective consuption
Maximum consuption
Open circuit voltage
Welding current
Duty cycle 25%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
TECHNICAL DESCRIPTION
MS 2000M
PRIMARY
230 V (+/- 10%)
50 Hz
13 A
32 A
SECONDARY
17,5 ÷ 33 V
35 ÷ 130 A
180 A
100 A
75 A
IP 23
H
Kg. 43,5
440 x 670 x 750 mm
EN 60974.1 / EN 50199
MS 2000T
PRIMARY
400 V (+/- 10%)
50 Hz
5,1 A
10 A
SECONDARY
19,5 ÷ 37 V
36 ÷ 170 A
170 A
105 A
85 A
IP 23
H
Kg. 43
440 x 670 x 750 mm
EN 60974.1 / EN 50199
Three phase supply
Frequency
Effective consuption
Maximum consuption
Open circuit voltage
Welding current
Duty cycle 30%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
Three phase supply
Frequency
Effective consuption
Maximum consuption
Open circuit voltage
Welding current
Duty cycle 30%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
3.3

STANDARD EQUIPMENT

- Earth cable
3.4

DUTY CYCLE AND OVERHEATING

The duty cycle is the percentage of a 10 minute period for which the welder can
continue to weld without overheating. If the machine overheats, the welding cur-
rent is shut off and the relative indicator lamp illuminates. In this case, leave the
machine to cool for approx. 15 minutes and, before restarting, lower the welding
current value and relative voltage or reduce the work time.
Example: 200A- 20% means working for 2 minutes at 200 A with 8 minutes rest
time.
3.5

VOLT - AMPERE CURVES

The volt-ampere curves show the welder's maximum output currents and voltage
(see page XVII.
(GB) 4
MS 2400T
PRIMARY
230 V
400 V
230V / 400 V (+/- 10%)
50 Hz
10,4 A
6 A
19 A
11 A
SECONDARY
17 ÷ 35 V
27 ÷ 200 A
200 A
140 A
110 A
IP 23
H
Kg. 71
500 x 870 x 950 mm
EN 60974.1 / EN 50199
MS 2800T
PRIMARY
230 V
400 V
230V / 400 V (+/- 10%)
50 Hz
10,4 A
6 A
19 A
11 A
SECONDARY
18 ÷ 40 V
35 ÷ 250 A
250 A
170 A
140 A
IP 23
H
Kg. 80
500 x 870 x 950 mm
EN 60974.1 / EN 50199
GB

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ms 2000tMs 2400tMs 2800t

Inhaltsverzeichnis