EN
1.0
DESCRIPTION AND TECHNICAL DESCRIP-
TION
1.1
DESCRIPTION
MIG/MAG welding professional generators, three-phase feeding,
forced ventilation, prepared for separated wire pulling set.
1.2
TECHNICAL DESCRIPTION
DATA PLATE
Three phase supply
Frequency
Effective consuption
Maximum consuption
Open circuit voltage
Welding current
Duty cycle 30%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
Three phase supply
Frequency
Effective consuption
Maximum consuption
Open circuit voltage
Welding current
Duty cycle 35%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
Downloaded from
www.Manualslib.com
DESCRIPTION AND TECHNICAL DESCRIPTION
250 A
PRIMARY
230 V
50 Hz
15 A
27 A
SECONDARY
18 ÷ 40 V
35 A ÷ 250 A
250 A - 26,5 V
170 A - 22,5 V
140 A - 21 V
IP 23
H
Kg. 77
mm 500 x 880 x 950
EN 60974.1 / EN 60974.10
300 A
PRIMARY
230 V
50 Hz
20 A
33 A
SECONDARY
18 ÷ 45 V
40 A ÷ 300 A
300 A - 29 V
230 A - 25,5 V
180 A - 23 V
IP 23
H
Kg. 93
mm 500 x 880x 950
EN 60974.1 / EN 60974.10
manuals search engine
Three phase supply
Frequency
Effective consuption
Maximum consuption
Open circuit voltage
Welding current
Duty cycle 35%
400 V
Duty cycle 60%
Duty cycle 100%
8,5 A
15,6 A
Protection class
Insulation class
Weight
Dimensions
European Standards
Three phase supply
Frequency
Effective consuption
Maximum consuption
Open circuit voltage
Welding current
Duty cycle 35%
400 V
Duty cycle 60%
Duty cycle 100%
11,3 A
19 A
Protection class
Insulation class
Weight
Dimensions
European Standards
1.3
STANDARD EQUIPMENT
For models 250A, 450A and 450AH
- Earth cable
For models 300A and 350A
- Earth cable
- Digital instruments
1.4
DUTY CYCLE AND OVERHEATING
The duty cycle is the percentage of a 10 minute period for which
the welder can continue to weld without overheating. If the ma-
chine overheats, the welding current is shut off and the relative in-
dicator lamp illuminates. In this case, leave the machine to cool for
approx. 15 minutes and, before restarting, lower the welding cur-
rent value and relative voltage or reduce the work time.
Example: 400 A - 60% means working for 6 minutes at 400 A with
4 minutes rest time.
1.5
VOLT - AMPERE CURVES
The volt-ampere curves show the welder's maximum output cur-
rents and voltage (see page XVI - XVII).
3 EN
350 A
PRIMARY
230 V
400 V
50 Hz
25 A
14,5 A
42 A
24 A
SECONDARY
18 ÷ 46 V
35 A ÷ 350 A
350 A - 31,5 V
270 A - 27,5 V
210 A - 24,5 V
IP 23
H
Kg. 108
mm 500 x 880 x 950
EN 60974.1 / EN 60974.10
450 A / 450 A H
PRIMARY
230 V
400 V
50 Hz
35,5 A
20,5 A
60 A
34,5 A
SECONDARY
19 ÷ 54 V
51 A ÷ 450 A
450 A - 36,5 V
345 A - 31,3 V
270 A - 27,5 V
IP 23
H
Kg. 140
mm 600 x 950 x 1050
EN 60974.1 / EN 60974.10