13. Standstill and storing

Standstill
During the standstill of the press no particular precautions have to be taken, which exceed the usual
valid regulations at appliances which are actuated with gas springs
Storing
For the transport or storage of the tool with a mounted STRACK nitrogen gas spring system, it is reasonable
to discharge the system pressure.
Please consider that, according to the construction, components of the tool, during a
longer storing, can uncontrollably be pushed together because of the lowering of the
system p ressure of the gas springs in the cam units (Accident Prevention Regulation).
Please check the system pressure of the gas spring before restarting the tool. If you have to increase the
system pressure, act as described in chapter 11.2.

14. Maintenance

Guide strips out of steel are hardened and normally are not submitted to any wear.
If necessary these strips are adjusted during the mounting in the company STRACK to guarantee a low guide
clearance.
The fixing screws of these strips are secured with the bolt adhesive Z9093.
The guide strips out of bronze with solid lubricant respectively sintered metal are submitted to a greater
wear compared with the steel strips.
The strips are produced in a narrow tolerance range. The exchange of these elements is thus effected without
a new adjustment. If both guide partners are exchanged, the guide clearance has to be examined and if
necessary has to be adjusted newly.