Herunterladen Inhalt Inhalt Diese Seite drucken

Gas Springs Which Can Optionally Be Received - Strack PowerMax SN5650-PMU-0330 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für PowerMax SN5650-PMU-0330:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PowerMax
I
Operating instructions -- PowerMax cam unit PMU
PowerMax cam unit SN5650-PMU-0330 — SN5650-PMU-1200

11.1 Gas springs which can optionally be received

Additional gas springs for the assembly in the driver can optionally be received to increase the stripper
forces.
At the cam width 460 mm, 1 gas spring with fastener is mounted in the driver, therefore this gas spring
is named SN5652-PMU-tye 1.
Concerning the cam widths 580 and 700 mm, 2 gas springs SN5652-PMU-type 2 can be mounted and for
the widths 850 and 1000 mm the stripper forces can be increased by 3 gas springs SN56562PMU-type 3.
Concerning the cam width 1200 mm the stripper forces can be increased by 4 gas springs SN5652-PMU-
type 4.
Please take the corresponding power indications from the catalogue. The PowerMax cams are already
prepared for the later mounting.
Move the gas springs in the intended boring. After that push the locking plate in the T-nut and fix it with
two safety screws.
Attention: Before tightening the screws, control that the bottom of the gas spring touches the machined
cast face.
26
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de