12.2 Increase of pressure / Charging of a gas spring
adapter M6-A
adapter M6-C
adapter M8
Please consider
Charging of gas springs
For gas springs with connector thread G1/8":
1. Turn the spindle screw back till the needle ends
flush in the centre of the connector G1/8".
2. Turn the charging equipment with the connector
G1/8" in the gas spring. Continue with step 3.
For the gas springs with the connecting thread
M6-A/M8:
2a Turn the adapter M6-A/M8 on the connecting
thread G1/8".
2b Turn the charging equipment with the connector
M6 in the gas spring. Continue with step 3.
28
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de
discharge valve
needle
Attention!
Minimum pressure 25 bar
Maximum pressure 175 bar
I
Operating instructions -- PowerMax cam unit PMU
manometer
onnector G 1/8"
3. Plug the coupling of the charging tube to the
quick coupling fitting.
4. Open slowly the valve at the charging tube
till the manometer shows the desired
pressure (close the valve).
5. The valve in the gas spring closes automati-
cally. To discharge the pressure which is
still in the charging equipment, turnthe
screw of the discharging valve slowly till the
residual pressure escapes. Finally turn the
adjusting screw of the discharging valve
immediately back to its initial position.
6. Turn the charging equipment out of the gas
spring.
PowerMax
spindle screw
quick coupling fitting
for charging tube

Werbung