8.2 INSULATION

Special measures for fire protection with combustible construction materi-
als (flooring and / or mounting walls) relating to the insulation.
The figure shows the installation situation using with
convection air housing as an example and applies as an
example for all fireplace inserts.
If and how the chimney walls in your
The fireplace cladding must
installation situation have to be insulated,
be suitable for heat dissipation
please consult your responsible stove fitter
(active surfaces or convection air
and the chimney sweeper.
openings)!
8 Insulation of the convection air housing all-around using, e.g., dimensionally stable mineral wool
according to the heat insulation thickness technical data.
13 Chimney cladding made from non-combustible construction material
23 Stud wall, 10 cm thick*
25 An insulation or air gap to protect flammable walls / walls requiring protection
must be included according to the chimney manufacturer's specifications
* If necessary, use a substitute insulation material (e.g. calcium silicate) in the place of front-mounted
masonry and insulation (point 8), in accordance with the technical data provided by the manufacturer.

9. CLEANING THE FIREPLACE SYSTEMS

Fireplace systems must be designed in such a manner that the air inlets
and air outlets can easily be cleaned and the distance area to the ceiling,
the walls and built-in furniture can be viewed easily and kept free. The
service openings must always be installed easy to access so that cleaning
is not made difficult.
10. SPECIAL INFORMATION FOR
SPARTHERM FIREPLACE INSERTS

10.1 FLUE GAS OUTLET

The flue gas outlet can be turned. It can be connected to the chimney
vertically as well as horizontally. For connecting to the side, there is a 90°
flue gas dome and a favourable 0 degree flue gas dome available in the
delivery program.