6.3 FIREPLACE MANTEL

A fireplace mantel must never be connected directly to the fireplace insert.
The apron must be self-supporting. Please note that there must be a min-
imum distance of 6 mm between the door frame and the fireplace hood/
installation frame in order to be able to disassemble the fireplace insert
door if necessary (e.g. replace the pane).

6.4 CONNECTING PIECE

The neck tube for the connection piece is on the flue dome of the fireplace
insert. The connection to the chimney must be carried out as directly as
possible and can be established vertically as well as horizontally. Connection
of the chimney must be carried out using a wall lining in the brickwork, or
arranged according to the specifications of the flue manufacturer. Connect-
ing pieces for house chimneys are made to shape from fire-clay or steel
piping (2 mm sheet steel according to DIN 1623, DIN 1298 and DIN EN 1856
is normally used).
NOTE
Requirements to the connecting piece in accordance with DIN 18160 Part 2.

6.5 HEAT DISSIPATION

Since it is possible to have different installation configurations with our
fireplace inserts, it is essential to consult a professional company when
planning a fireplace setup.. Make sure that the level of heat dissipation
is sufficient. This can be achieved by using convection air ducts in the
cladding, via heat-dissipating cladding elements or using a combination
of both.

6.5.1 HOT AIR SYSTEMS

Fireplace systems designed to transfer heat generated by convection (stoves,
fireplaces, etc.) must comply with the following points:
• The cross-section for the air inlet opening and for the air outlet opening
must be obtained from the technical data. Deviating cross-sections are
possible on calculated verification.
• It must not be possible to close at least 50% of the air inlet and air
outlet openings.
• Convection air jackets must be attached at all four connecting stubs.
It must not be possible to close the air inlet and air outlet openings.
• A ir circuit pipes must be manufactured from a non-flammable,
non-deformable material.
• No flammable objects or materials (wooden ceiling components, furni-
ture) may be positioned within an area 30 cm to the side of, and 50 cm
above the system hot air discharge grilles.