7.1 FLOORS AND WALLS

11
13
12
10
14
16
15
8 Insulation of the heating chamber according to the heat insulation technical data.
9 If necessary, wall sleeve with sealing cord
10 Exhaust pipe (connecting piece)
11 Supply air grille (hot are outlet) The position must be selected in such a manner,
that a distance of 500 mm is between the top edge of the grille and the ceiling..
12 Chimney breast
13 Chimney system cladding made from non-combustible construction material
14 Mounting frame with insulation strips
15 Separate combustion air connection
16 Air circulation grille (cold air supply)
8
9
GB 23

7.2 FLOORS, WALLS AND CEILING

21
8
The fireplace cladding
must be suitable for heat
dissipation (active surfaces or
11
convection air openings)!
13
17
12
14
16
15
8 Insulation of the heating chamber all-round
according to the heat insulation technical data.
9 If necessary, wall sleeve with sealing cord
11 Supply air grille (hot are outlet) The position
must be selected in such a manner,
that a distance of 500 mm is between the top
edge of the grille and the ceiling.
12 Chimney breast
13 Chimney cladding made from non-combustible
construction material
14 Mounting frame with insulation strips
15 Separate combustion air connection
18
9
20
19
16 Air circulation grille (cold air supply)
17 Insulated flue gas pipe (connecting piece)
with at least 3 cm thick dimensionally stable
mineral wool
18 Insulation of the connecting lines with
at least 3 cm thick dimensionally stable
mineral wool
19 Convection air housing
20 Top insulation of the convection air housing
min. 3 cm
21 Observe the air return!
GB