Herunterladen Inhalt Inhalt Diese Seite drucken

Loading Door; Self Closing And Non Self-Closing Door - Spartherm Premium V-FD-87h Aufbauanleitung

Kamineinsätze
Vorschau ausblenden Andere Handbücher für Premium V-FD-87h:
Inhaltsverzeichnis

Werbung

1.1 LOADING DOOR

The suitability of the fireplace insert for multiple allocation (two or more
fireplace inser ts on the same chimney) depends on if the door has a
self-locking function:
Self-locking door function: fireplace insert is suitable for multiple allocation
No self-locking door function: multiple allocation is not permitted, thus,
the fireplace insert must be connected to its own chimney line.
Note: with a multiple allocation of the chimney, this must be built and
designed accordingly.
In doing so, the question must be asked if the fireplace insert is an "open
fireplace" or not. In Germany, an "open fireplace" is not subject to the
emission requirements of the BImSchV level 1 (Ordinance in the Imple-
mentation of the Federal Emission Control Act), but may be operated
"occasionally". The manufacturer specifies the mode of operation of the
fireplace insert and determines if the device can be used correctly when
open and thus must be termed as "open chimney": open burning permitted
according to the manufacturer: open fireplace only with occasional opera-
tion of open burning according to the manufacturer is not permitted: closed
chimney, not limitations in use.
Note: the former terms from "Design A1" or "Design A" that are derived
from the standard DIN 18895 that is no longer valid frequently resulted in
the mixture of the features specified above and are no longer valid.
Generally, Spartherm fireplace inserts are operated correctly when the
loading door is closed. thus, with the exception of feeding or cleaning, the
fireplace insert doors must be shut.
Fireplace inserts for burning with loading door open tested by our-
selves are marked in the installation instructions for the fireplace
insert enclosed separately in the technical data.
When operating on a chimney with single allocation (one fire area
for each chimney line), the operator can choose if the combus-
tion chamber door is self-locking or not self-locking. The correct
position of the loading door when operating the fire is always the
responsibility of the operator and must be observed.

1.1.1 SELF CLOSING AND NON SELF-CLOSING DOOR

Spartherm inserts equipped with a sliding door are not self-closing when
delivered, Fireplace insert with a hinged do have a self closing installed.
The fireplace inserts with sliding door can be converted to a self closing
door by removing some of the door counter weights.
Hinged door inser ts can be conver ted to non-self closing by relieving
the door spring. The door locking type with folding fireplace insert with
non-locking combustion chamber door can be converted into a self-locking
combustion chamber door by relieving the door closing spring.
The next chapter will show you how to do this.