INSTALLATION
Specification
18.5 Pressure drop
Taps
Tap pressure drop at a flow rate of 10 l/min
Mono lever mixer tap, approx.
Thermostatic valve, approx.
Shower head, approx.
18.7 Energy consumption data
Product datasheet: Conventional water heaters to regulation (EU) no. 812/2013 and 814/2013
Manufacturer
Load profile
Energy efficiency class
Energy conversion efficiency
Annual power consumption
Default temperature setting
Sound power level
Special information on measuring
efficiency
Daily power consumption
www.stiebel-eltron.com
MPa
0.04 - 0.08
MPa
0.03 - 0.05
MPa
0.03 - 0.15
DHE Connect 18/21/24
234467
STIEBEL ELTRON
S
A
%
39
kWh
480
°C
60
dB(A)
15
Measured at ECO level at
highest flow rate, maximum
output and maximum set
value.
kWh
2.211
Sizing the pipework
When calculating the size of the pipework, an appliance pressure
drop of 0.1 MPa is recommended.
18.6 Fault conditions
In the event of a fault, loads up to 80 °C at a pressure of 1.0 MPa
can occur briefly in the installation.
DHE Connect 27
DHE Touch 18/21/24
234468
STIEBEL ELTRON
S
A
39
481
60
15
Measured at ECO level at
Measured at ECO level at
highest flow rate and maxi-
highest flow rate, maximum
mum set value
output and maximum set
2.217
DHE Touch 27
234459
STIEBEL ELTRON
STIEBEL ELTRON
S
A
39
480
60
15
Measured at ECO level at
highest flow rate and maxi-
mum set value
value.
2.211
DHE Connect | DHE Touch |
234460
S
A
39
481
60
15
2.217