OPERATION
Settings
Dynamic anti-scalding protection
With the dynamic anti-scalding protection, after selecting a tem-
perature on the appliance or wireless remote control, the user
has automatic priority for setting the maximum temperature. The
priority is active for 2 minutes or until 2 minutes after the current
draw-off ends. After this, priority is automatically disabled.
During the priority period, you can reduce the temperature or
increase it to a maximum of 43 °C using other wireless controls.
4.2

Recommended settings

The appliance meets high demands regarding comfort and tem-
perature accuracy. Should you nonetheless be operating the ap-
pliance with a thermostatic valve, we recommend that you:
f Adjust the set temperature on the appliance to over 50 °C.
f
Then set the required set temperature on the thermostatic
valve.
Saving energy
The following recommended settings will result in the lowest en-
ergy consumption:
- 38 °C for hand washbasins, showers, bath
- 55 °C for kitchen sinks
72
|DHE Connect | DHE Touch   
Internal anti-scalding protection (qualified contractors)
If required, the qualified contractor can set a permanent temper-
ature limit, for example in nurseries, hospitals, etc.
When supplying a shower, the appliance temperature setting
range must be adjusted by the qualified contractor to 55 °C or less.
Limiting it in this way prevents water from flowing out of the
appliance at temperatures which could cause injury.
Following an interruption to the water supply
Material losses
!
To ensure that the bare wire heating system is not dam-
aged following an interruption to the water supply, the
appliance must be restarted by taking the following steps.
f Isolate the appliance from the power supply; do this
f
by removing the fuses or switching the appliance to
"OFF".
f Open the tap for one minute until the appliance and
f
its upstream cold water inlet line are free of air.
f Switch the power supply back on, or set a tempera-
f
ture on the appliance or wireless remote control.