Herunterladen Inhalt Inhalt Diese Seite drucken

STIEBEL ELTRON DHE Connect 18/21/24 Bedienung Und Installation Seite 110

Vorschau ausblenden Andere Handbücher für DHE Connect 18/21/24:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
INSTALLATION
Troubleshooting
Diagnostic lights
Fault
Green flashing, yellow
No DHW; the outlet temper-
on, red off
ature does not match the set
value.
Green flashing, yellow
No DHW; the outlet temper-
off, red on
ature does not match the set
value.
Note
The "PROFI DIRECT" app for fast troubleshooting is avail-
able from the App Store.
110
|DHE Connect | DHE Touch   
Cause
The downstream tap is faulty.
Internal anti-scalding protection is activated.
The heating system is faulty.
The outlet sensor is faulty.
The PCB is faulty.
The safety switch is not enabled during "Initial start-
up".
The safety switch has tripped.
Not all phases are connected to the appliance.
The NTC sensor is faulty.
Remedy
Replace the faulty tap.
Deactivate the internal anti-scalding protection.
Replace the test assembly.
Replace the outlet sensor.
Replace the test assembly.
Activate the safety switch by firmly pressing the reset
button.
Remedy the cause and activate the safety switch.
Check the fuses/MCBs.
Check the NTC, replace the sensor if necessary.
www.stiebel-eltron.com

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis