5.3 Programming Mode "PROG"
• When the Door Controller is working in "programming mode" the "PROG" red led is
on whereas the other two red leds are off.
• Press contemporaneously Key 1 and Key 4 for few seconds to enter the programming
mode. The display on the Door Controller will show "P" and "00" flashing alternately.
• When the Door Controller is in programming mode, all signals coming from the main
lift controller and from the external devices (barriers, photocells,...) are ignored.
• The parameter to be modified is selected by means of the increasing and decreasing
KEYs, respectively the buttons 2 and 3; this parameter is then confirmed by pushing
the key 1, ENTER.
• After confirming the parameter to be modified, the display shows the relevant nume-
ric value.
• Modify the chosen parameter using the key 2, increase, and 3, decrease, and confirm
the changes by pressing key 1 ENTER.
• At the end of the necessary configurations, use the key 4 pressing to select the requi-
red operating mode (manual "MAN" or automatic "AUTO").
The following table contains the available parameters, the relevant codes,
the description and the allowed modification range:
Param.
Default
codes
00
00
01
00
02
00
03
00
04
00
05
00
06
00
07
00
08
00
09
66
10
50
11
50
12
50
© SEMATIC
All rights reserved
Changes can be made without notice
see www.sematic.com for latest release
Parameter
Reversing system choice
Main Lift Controller Test
No MLC signal;
MLC Input Alarm
Limited Door Reversal Effect
Car door locking device
Glass doors
Aux Output Relay
Space Percentage
(Percentage of the available
space to operate the AUX relay)
Reversing force setting
Opening High Speed
Opening Low Speed
Opening "comfort
infosem@sematic.com
Range
Note
00
01
00
,
-> Internal
01
-> External
00
01
02
00
,
,
-> When Moving
01
-> Moving + Parking
02
-> Off
00
01
00
,
,
-> Instant Stop
01
-> Low Speed to Stop
02
-> Low Speed Cycle
00
01
00
,
,
-> Off
01
-> On
00
01
00
,
,
-> Off
01
-> On
00
01
00
,
,
-> Off
01
-> On
00
01
00
,
,
-> Off
01
-> On
00
01
02
00
,
,
-> Off
01
-> Gong While opening
02
-> according to % of space
00
99
00
99%
..
..
00
(
= closing limit)
10-150 N (10-135 N U.S. version)
00..99
01
99
..
01
99
..
01
99
..
17
w w w . s e m a t i c . c o m

Quicklinks ausblenden: