Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning And Servicing; Call-Up Of Calibration Menu; Spare And Wearing Parts - Beissbarth MT 826 DT Originalbetriebsanleitung

Radwuchtmaschinen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
54 | MT 826 DT | Maintenance
12. Maintenance
12.1

Cleaning and servicing

!
Before cleaning and servicing, switch off
MT 826 DT and disconnect mains plug.
!
Do not use any solvent-based cleaning agents. Use
alcohol or similar cleaning agents for plastic parts.
The following work is essential to ensure proper
operation and high performance of the MT 826 DT:
Servicing
Clean moving mechanical parts, treat with spray oil
or kerosene and lubricate with engine oil or a suitable
grease.
12.2

Spare and wearing parts

The manufacturer cannot accept any liability for
damage arising from the use of non-genuine
replacement parts.
Designation
Standard centering flange
Centering cone 42 - 65 mm
Centering cone 54 - 80 mm
Centering cone 75 - 110 mm
Weight pliers
Manual vernier caliper
Test clip
Calibration weight
Calibration weight (calibrated)
Voltage sticker V 230
Voltage sticker V 110
Direction of wheel rotation sticker
Tab. 2:
Spare and wearing parts
|
1 695 600 575
2016-08-23
12.3
i
As part of service and upkeep (every six months), on
flange replacement or in the event of measurement
inaccuracies, it is advisable to calibrate the
MT 826 DT in the following sequence:
1. Flange calibration.
2. Calibrate the electronic vernier caliper.
3. MT 826 DT calibration.
4. Perform reference measurement.
12.3.1
1. Call up the "Settings and service" menu.
x
2. Enter the password: <r> <r> <o>.
"
The calibration menu is displayed.
Calibration with "Go" wheel
Flange calibration
Order number
1 695 602 400
Return to main page.
1 695 632 500
1 695 652 862
Electronic vernier caliper and Angular width gauge
1 695 605 600
calibration
1 695 606 500
1 695 629 400
1 695 602 700
12.3.2
1 695 654 377
1 695 654 376
i
Follow the instructions shown on the monitor.
1 695 101 269
1 695 100 854
1. Fit the flange (refer to Section 5).
1 695 653 878
i
Do not clamp the wheel, do not use any clamping
tools.
2. Select flange calibration and confirm with < I >.
 Calibration is started.
3. Close the wheel guard.
 Measurement commences.
"
Flange calibration completed.
"
Unbalance set to "0".
Calibration

Call-up of calibration menu

Flange calibration
Beissbarth GmbH