6.
Maintenance
6.1
Suggested lubricants
Component
Lubricant
Gearbox
ESSO Spartan EP460 ISO 460
Hydraulic pump
ESSO NUTO H 46
Pneumatic sys-
ESSO FEBIS K 32
tem (conditio-
ning assembly)
Tab. 1:
Lubricants table.
!
The manufacturer is not liable for any damage
caused by use of lubes different from those shown in
the table.
6.2

Cleaning and servicing

Before any cleaning or maintenance interven-
tion, disconnect the MS 80 by means of the
main switch and disconnect the network.
To guarantee full efficiency of the MS 80 and to ensure
functioning without anomalies it is essential to clean
the machine regularly and carry out periodical mainte-
nance.
Maintenance has to be carried out by the operator
in accordance with the manufacturer's prescriptions
shown here below.
6.2.1
Service intervals
Maintenance
Charge completely the remote control battery.
Clean the mechanical moving parts, spray
them with nebulized oil or kerosene and lube
with appropriate grease
Remove condensate.
Check oil level in the oil nebulizer.
Check transmission belt tensioning in order to
avoid its sliding.
Check the oil level of the hydraulic control
unit and keep it always between minimum and
maximum
Check and maintain the grease level on the
self-centering and on the tool holding arm.
Lubricate with grease the sliding rail of the
trolley.
Change oil in the oil nebulizer.
Beissbarth GmbH
Standard
DIN 51502-CLP
ISO 34-98-CC
ISO 46
6.2.2
DIN 51502-HLP
1. Power off the equipment;
DIN 51524 PART.2-
2. Unscrew the cap with measuring rod on the hydrau-
HLP
ISO 67-43-HM
3. Check that the oil level is between MIN and MAX.
ISO VG 32
6.2.3
1. Put a container underneath the gearbox.
2. Unscrew the microswitch under the tool holding
3. Unscrew the oil discharge screw.
4. Discharge oil in the gearbox and dispose it (see
5. Unscrew the microswitch under the tool holding
6. Top up with new gearbox oil (see lube table).
7. Screw the oil discharge screw.
6.2.4
1. Turn left the red button placed in the lower part of
2. Remove the accumulated condensate.
3. Turn back in previous position the red button placed
6.2.5
1. Disconnect pneumatic connection.
2. Unscrew the tank cap on the oil nebulizer.
3. Top up oil (see lube table).
x
x
x
x
x
x
6.2.6
1. Disconnect pneumatic connection.
x
2. Unscrew the tank cap on the oil nebulizer.
x
3. Discharge oil and dispose it (see chap. 7.3).
4. Top up with new oil (see lubricant table).
x
Maintenance | MS 80 | 45
Maintenance
Change the oil in the hydraulic control unit.
Check the gearbox oil level.
Check the hydraulic control unit oil level
lic control unit.

Gearbox oil change

arm;
chap. 7.3).
arm;
Condensate removal
the water separator.
in the lower part of the water separator.
Nebulizer oil refill
Change oil in the oil nebulizer