1.5 Nameplates

All pumps can be identified by means of the nameplate on the
motor top cover, see fig. 1. If the nameplate is missing or dam-
aged, the pump can be identified by the serial number stamped
under the nameplate.
Type:
1
2
Prod. No:
3
No:
Hmax:
m
5
7
20 m
9
Motor: ~
10
13
P1:
kW
14
f
Cos :
16
P1:
18
Fig. 1
SEN nameplate
Pos.
Description
1
Type designation
2
SAP code
3
Serial number
4
Maximum liquid temperature
5
Maximum head
6
Maximum flow
7
Maximum installation depth
8
Enclosure class
9
Number of phases
10
Frequency
11
Rated speed
12
Voltage/current, delta connection
13
Voltage/current, star connection
14
Power input
15
Shaft power
16
Power factor
17
Insulation class
18
Production code, year/week
19
Weight of the pump
10
4
Tmax:
°C
6
Qmax:
l/s
8
IP68
1
Hz
n:
min
11
12
A
A
P2:
kW
15
17
Insul.class:
19
wt:
kg
96066955
1.5.1 Ex certification and classification
Explosion-proof pumps have been approved by Baseefa (2001)
Ltd. in conformity with the essential health and safety require-
ments relating to the design and construction of equipment
intended for use in potentially explosive atmospheres given in
Annex II to the Council Directive 94/9/EC (ATEX).
The certified pumps (Ex-pumps) are supplied with an approval
plate fixed in the visible place close to the nameplate.
Fig. 2 shows the approval plates for the pumps equipped option-
ally with the motors classified to T3 or T4 temperature class.
CE 1180
II2 G
EEx dIIB T3
cIIB T4
Baseefa
Type:
No.
PC
Cautions!
Do not open while energized
Cable temp. may exceed 70 °C
ZZ 325B
96496551
Fig. 2
SEN Ex approval plates
The approval plate gives the following details:
CE
CE mark.
1180
Number of Quality Assurance notified body.
EU ex-symbol.
II
Equipment group (II = non-mining).
2
Equipment category (high protection).
G
Type of explosive atmosphere.
EEx
Motor explosion-proof according to European standard.
d
Motor withstands explosion pressure.
IIB
Gas Group.
T3
Maximum surface temperature of the motor is 200°C.
T4
Maximum surface temperature of the motor is 135°C.
c
Constructional safety.
Baseefa Certificate number.
No.
HA.
PC
Production code.

2. Safety

Pump installation in pits must be carried out by
specially trained persons.
Persons should not enter the installation area when
an explosive atmosphere is present.
For safety reasons, all work in pits must be supervised by a per-
son outside the pump pit.
Pits for submersible wastewater pumps contain wastewater with
toxic and/or disease-causing substances. Therefore, all persons
involved must wear appropriate personal protective equipment
and clothing and all work on and near the pump must be carried
out under strict observance of the hygiene regulations in force.
CE 1180
II2 G
EEx dIIB T4
cIIB T4
Baseefa
Type:
No.
PC
Cautions!
Do not open while energized
Cable temp. may exceed 70 °C
Do not open when an explosive
gas atmosphere is present.
ZZ 325A
96496550