Fitting the water filter cartridge

The water filter is located at the top right in the fridge.
Open the cover.
D
Remove the blue bypass cover.
D
Retain for future use.
Remove the filter packaging and insert the filter
D
cartridge. Turn the filter cartridge clockwise
until the filter locks in place.
Close the cover.
D

Aligning the appliance

To ensure that the appliance functions correctly, it must
be set level with a spirit level.
Note:
To ensure that the door closes tightly, the appliance
should stand 6 mm lower at the back than at the
front.
An incorrectly aligned appliance can result in water
running out of the ice maker, ice cubes of unequal size
being produced or the doors not closing properly.
1
Place the appliance in the designated location.
3
2
With a size
/
" (9.5 mm) Allan key, turn the two
8
adjusting screws (A) to raise or lower the front of the
fridge.
3
With an Allan key, turn the two adjusting screws (B)
to raise or lower the back of the fridge.
4
With a spirit level check:
Whether the appliance is level on the sides.
Whether the appliance is 6 mm lower at the back.
Standard: Half a spirit level bubble.