Fault
No water or ice is dispensed.
Ice maker does not produce
enough ice or ice does not have
g
the correct shape.
Ice maker does not make any ice.
66
Possible cause
Freezer compartment door is not
closed. Control panel is not supplied
with power.
Ice and water dispenser is locked via
the control panel.
Water tank being filled.
Appliance or ice maker has just been
switched on.
A large amount of ice was removed.
Water filter clogged or spent.
Appliance or ice maker were only just
switched on.
A large amount of ice was removed.
Low water pressure.
Water filter clogged or spent.
Arm of ice maker is in the upper
(OFF) position.
Appliance is not supplied with water.
Water supply hose has kinks.
Low water pressure.
Temperature in freezer compartment
too high.
Ice cube container is not correctly
inserted.
Incorrect shut off valve fitted.
The manufacturer is not responsible for damage to property caused
by incorrect installation or incorrect water connection.
Remedial action
Close the door.
Deactivate lock.
When used for the first time, it takes
about 2 minutes until the tank is full.
It takes about 24 hours until ice
production starts.
It takes about 24 hours until the
ice cube container is refilled.
Changing the water filter
It takes about 24 hours until ice
production starts.
It takes about 24 hours until the
ice cube container is refilled.
The water pressure must be between
0.14 MPa (1.4 bar) and 0.69 MPa
(6.9 bar) so that the appliance
functions properly. When using the
water filter, the water pressure must
be between 0.24 MPa (2.4 bar) and
0.69 MPa (6.9 bar).
Changing the water filter
Push down the arm (ON).
Contact an electrician or the water
supply company.
Shut off water supply at the shut off
valve, smooth out kinks or have hose
replaced.
The water pressure must be between
0.14 MPa (1.4 bar) and 0.69 MPa
(6.9 bar) so that the appliance
functions properly. When using the
water filter, the water pressure must
be between 0.24 MPa (2.4 bar) and
0.69 MPa (6.9 bar).
The temperature in the freezer
compartment should be between
-17 ºC and -18 ºC, regulate
if necessary.
Check position, reinsert if necessary.
Incorrect valves can give rise to a low
water pressure and damage the
appliance.