Herunterladen Inhalt Inhalt Diese Seite drucken

Renishaw SP25M Bedienungsanleitung Seite 136

Vorschau ausblenden Andere Handbücher für SP25M:
Inhaltsverzeichnis

Werbung

SP25M user's guide
http://www.renishaw.com
Module
Low force (LF)
Standard force (SF)
Medium force (MF)
Extended force (EF)
6-way
EM1
EM2
TP20 installation
Assembling the probe module and stylus
1. Select the probe module with the correct trigger force rating for the application (see 'TP20 module selector' section).
2. Fit the stylus to the probe module, first hand tightening then using the S7 stylus tool (supplied) for final tightness. Renishaw GF styli
require an S20 spanner. The recommended tightening torque is 0.05 Nm to 0.15 Nm (0.04 lb ft to 0.11 lb ft). Torque must not exceed 0.3
Nm (0.22 lb ft).
Fitting the probe module with stylus on the RTP20
1. Examine all mating faces for cleanliness. Where necessary, clean the surfaces with the Renishaw CK200 kit (supplied).
2. The TP20 module and kinematic mount are marked with three unique alignment marks. When offering the TP20 up to the probe head,
ensure that similar marks are aligned with each other. Allow the TP20 body to engage under magnetic force.
Issued 10 2015
Minimum stylus length
10 mm (0.39 in)
10 mm (0.39 in)
10 mm (0.39 in)
10 mm (0.39 in)
10 mm (0.39 in)
10 mm (0.39 in)
10 mm (0.39 in)
Maximum stylus length
30 mm (1.18 in)
50 mm (1.97 in)
60 mm (2.36 in)
60 mm (2.36 in)
30 mm (1.18 in)
50 mm (1.97 in)
50 mm (1.97 in)
Overall reach
94 mm (3.70 in)
114 mm (4.49 in)
124 mm (4.88 in)
124 mm (4.88 in)
98 mm (3.86 in)
143 mm (5.63 in)
168 mm (6.61 in)
136