SP25M user's guide
http://www.renishaw.com
System components overview
System overview
The modular design of the SP25M system enables the flexibility for optimum configuration by the user. Please refer to the schematic
diagrams showing the SP25M system components in the SP25M installation section of this document.
SP25M probe body
The SP25M probe body houses the optical transducer system and attaches to PH10M PLUS, PH10MQ PLUS or PH6M using a Renishaw
autojoint connection.
SM25 scanning modules
There are five scanning modules in the SM25 range which enable accurate scanning measurements at different stylus lengths. SM25-1,
SM25-2, SM25-3 and SM25-4 are recommended for use with linear stylus arrangements and SM25-5 is recommended for use with non-
linear and star stylus arrangements.
SH25 stylus holders
The range of SH25 stylus holders enable accurate scanning measurements with effective stylus lengths ranging from 20 mm to 400 mm.
SH25-1, SH25-2, SH25-3 and SH25-4 are recommended for use with linear stylus arrangements. SH25-2A, SH25-3A, SH25-4A and
SH25-5 are recommended for use with non-linear and star stylus arrangements.
TM25-20 adaptor module
For rapid touch-trigger measurement, the TM25-20 adaptor module may be used which provides full compatibility with the whole range of
TP20 touch-trigger probe modules.
FCR25 flexible change rack
Automated and repeatable changing of the SM25 scanning modules, SH25 stylus holders and TM25-20 is possible with FCR25. This triple
port system is designed for mounting on the Renishaw MRS rail system.
FCR25-L3 and FCR25-L6 leg mounted flexible change racks
These variants of the FCR25 flexible change rack and designed to be mounted to the bed of the CMM with the integrated leg assembly.
FCR25 TC change rack
The FCR25 TC provides automated and repeatable changing of SM25 scanning modules whilst keeping the ports at the same operating
temperature as the SP25M probe body. This ensures that there is no difference in temperature between the SP25M probe body and the
SM25 scanning modules eliminating thermal variation and providing optimum metrology.
AC3 analogue interface PCB card
An ISA bus card to enable integration of the SP25M system with a CMM manufacturer's own controller.