7.8. Cleaning the generating set
Remove all dust and debris from around the exhaust and clean the generating set using a cloth and a brush (cleaning with a water
jet is not recommended, and cleaning with high-pressure cleaning equipment is forbidden).
Carefully clean the motor air inlets and outlets and the alternator.
Check the general condition of the generating set and, if necessary, replace any faulty parts.

8. Storing the generating set

Generating sets which are to remain unused for more than 30 days must undergo certain procedures in order to keep them in good
condition.
While the engine is still hot, drain the oil from the sump and replace it with new oil of suitable quality.
Disconnect the engine fuel pipe and place the free end of the pipe in an approved container.
Open the fuel tap (no. 6, fig. C) and drain the fuel into the container.
Close the fuel tap, then re-connect the fuel pipe to the engine.
Undo the drain screw (no. 1, fig. G) of the carburettor and drain the carburettor into an approved container.
After draining, replace the carburettor drain screw.
Remove the 2 spark plugs and pour approximately 15 ml of engine oil into the cylinder. Replace the plugs and turn the engine
over to distribute the oil. Then clean the generating set and cover the alternator air inlets and outlets with plastic adhesive tape.
Remove the battery and store it somewhere dry. Recharge it once a month.
Store the generating set in a clean, dry place.

9. Fault finding

The generating set is on charge during start-up
The engine will
Not enough petrol or oil
not start
The fuel tap is closed
Fuel supply blocked or leaking
Blocked air filter
The engine cuts
Blocked ventilation inlets
out
Possible overload
Circuit breaker tripped out
No electric
Faulty circuit breaker
current
Faulty plug sockets
Faulty appliance leads
Faulty alternator
Circuit breaker
Generating set overload
trips out
Faulty equipment or lead
Probable causes
Probable causes
Probable causes
Probable causes
Remedial action
Take it off charge
Fill up with petrol or oil
Open the fuel tap
Have the system repaired
Clean the air filter
Remedial action
Clean the air inlet and outlet guards
Check the load
Remedial action
Re-set the circuit breaker
Have it checked, repaired or replaced
Have them checked, repaired or replaced
Change the leads
Have it checked, repaired or replaced
Remedial action
Reduce the load
Have it checked, repaired or replaced