Faults

NOTICE
It is normal for a few drops of water to escape from the
mechanical seal from time to time. This is especially true during
the break-in period.
Depending on the water quality and number of operating hours,
the mechanical seal can begin to leak.
If water leaks constantly, have the mechanical seal replaced
by a qualified technician.
7.1

Overview

Fault: Motor overload
Possible cause
Dynamic head lower than
that indicated in the
order.
Higher density of the
pumping liquid than that
indicated in the order.
Too high a speed.
Running on two phases.
Transport fuse not
removed from the shaft
groove.
Fault: Too high a pump pressure
Possible cause
Too high a speed.
04/2019
Solutions
Set operating point exactly.
For constant overload turn the
impeller - (further enquiry
required).
Contact manufacturer.
Reduce speed - (further enquiry
required).
Renew faulty fuse.
Check the electrical connections
using the operating manual.
Remove the transport fuse from
the shaft groove.
Solution
Reduce speed - (further enquiry
required).