UK | 2 General notes
PP 45 units are available in the following
models: "O" for object, "K" for comfort and
"RC" for radio-controlled. The ventilation units
are installed in outdoor walls and connect-
ed to a permanent electrical installation. To
achieve efficient
ventilation, we would recommend operating
the units in pairs with alternating ventilation
and air extraction.
The units are operated using an RLS../DS..
room air control suitable for the type:
● PP 45 O / PP 45 K units are operated with
an RLS 45 O or RLS 45 K control.
● PP 45 RC units are operated using a DS 45
RC radio switch (alternatively with RLS 45 K
+ radio extension module PP 45 EO).
PP 45 ventilation units are only intended for
domestic use and similar purposes. No other
or additional use is intended.
56

2.4 Non-intended use

The ventilation unit must not be used in
the following situations under any circum-
stances. Read all the safety instructions.
DANGER
!
Electric shock from water ingress if
!
used in protection zone 0, 1 or 2.
 Only use ventilation units and room air
controls outside protective zones 0, 1 or 2.
Risk of combustion/fire from flam-
!
mable materials, liquids or gases in the
vicinity of the ventilation unit.
 Do not place any flammable materials, liq-
uids or gases near the ventilation unit, which
may ignite
in the event of heat or sparks and
catch fire.
Risk of death if an air-ventilated fire-
!
place is connected to an exhaust gas
system, which itself has multiple connec-
tions.
The air-ventilated fireplace may result in ex-
haust fumes being transferred to other living
units. Risk of death, for example from carbon
monoxide.
 Never use ventilation unit if there are
air-ventilated fireplaces in the living unit
that are connected to exhaust gas systems,
which themselves have multiple connections.
Risk of explosion
!
Explosive gases and dusts may ignite and
cause serious explosions or fire.
 Never use ventilation unit in an explosive
atmosphere.
Risk of explosion
!
Explosive substances in lab extraction units
may ignite and cause serious explosions or
fire. Aggressive substances may damage the
ventilation unit.
 Never use ventilation unit in combination
with a lab extraction unit.