2.1.3. Menu Trace

F1 Trigger: AUTO
F2 RecTele: 0000
F3 _Start, *Stop
F4 Send Buffer
F1 Trigger: AUTO
F2 RecTele: 0000
F3 _Start, *Stop
F4 Send Buffer

Menu Trigger

F1 Trigger: AUTO
F2 Node-IDs:
3,4,12,103
F3 Msg: NMT
F1 Trigger: AUTO
F2 Node-IDs
F3 Msg: NMT
Displays the current trigger mode. With the F1 key the trigger mode and the
trigger conditions can be changed (=> menu "Trigger").
Enables to look at the messages transferred via the bus with the key F2. The
number of the received messages is indicated right-aligned.
Since the buffer can only contain 1024 messages the first messages are
overwritten by current messages if this number is exceeded.
Starts or stops the writing of the current messages transferred via the bus
into the buffer. If the trigger type is not set to "AUTO", starting or stopping the
writing into the buffer depends on the occurrence of the trigger condition
according to the selected trigger type. "*" before "_Start" or "_Stop" indicates
the current state "Reception" or "Reception stopped". "!" at the end of the 4th
display line (after "F4 Send Buffer") indicates that the bus transmission is
disturbed (error frames were received).
Sends the buffer contents to the CAN bus. This is done to transfer and
further process the traced messages, e.g. to an external PC.
Selection of the trigger type (=> menu "Trigger type").
Input of max. four node addresses whose messages release triggering or "0"
for all node addresses.
Selection of the message type which releases triggering (=> menu "trigger
message").