Charging the battery with a charger socket ( o )
4.2
Charging
WARNING!
The gases produced during charging
can cause explosions
Always check the fans each time you
charge.
Requirements
– Truck parked securely, (see "Parking the
truck securely" on page 73).
Procedure
• Connect the charger lead of the battery charger station to the charger socket (55).
Z
Test the fan. If the fan is not working, open the cover to ventilate the battery
compartment.
• Depending on the battery you may need to attach the water connection (56) to the
battery charger station.
• Switch on the battery charging station and charge the battery in accordance with
the battery and charging station manufacturers' instructions.
Z
After charging, test the fans and remove the connector. If the fan is not working,
open the cover to ventilate the battery compartment.
Z
Use only chargers with a max. 160 A charging current.
Battery is charged.
55
56