Technical data

determined in accordance with EN 15033 or Truma test
conditions
Manufacturer
Truma Gerätetechnik GmbH & Co. KG
Postfach 1252
85637 Putzbrunn (Munich)
Germany
Protection class
IP21
Water capacity
10 litres
Pump pressure
max. 2.8 bar
System pressure
max. 4.5 bar
Gas type
Liquid gas (propane / butane)
Operating pressure
30 mbar
Nominal heat load
Q
= 1.5 kW (H
); 120 g/h; C
n
i
Heating time from approx. 15 °C to approx. 70 °C
Gas mode:
Electrical mode:
Gas and electrical mode:
Power supply
12 V
230 V
/ 50 Hz
Power consumption at 12 V
Ignition:
0.16 A
Heating:
0.12 A
Standby:
0.05 A
Power consumption at 230 V
Heating: (3.7 A) 850 W / (5.7 A) 1300 W
Standby – gas consumption
approx. 70 W
Weight without water
(Boiler gas)
6.9 kg
(Boiler gas/electric)
7.4 kg
Destination countries
AT, BE, BG, CH, CY, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HR,
HU, IE, IS, IT, LI, LT, LU, LV, MT, NL, NO, PL, PT, RO, SE, SI,
SK, TR
E1 10R-05 2604
Subject to technical changes.
; I
11
3B/P(30)
approx. 31 min.
approx. 29 min. (BGE 10)
approx. 16 min. (BGE 10)
(Boiler gas/electric)
17