Safety instructions

– Operate the Truma CP plus VarioHeat control panel only if it
is in a technically perfect condition.
– Repairs must be carried out immediately. Only carry out
repairs yourself if the solution is described in the trouble-
shooting guide of this operating instructions.
– Do not carry out any repair work or modifications on the
Truma CP plus VarioHeat control panel.
– A defective Truma CP plus VarioHeat control panel may only
be repaired by the manufacturer or the manufacturer's ser-
vice department.
– Never use LP gas appliances when refuelling, in multi-storey
car parks, in garages, or on ferries. Switch off the LP gas
appliance on the Truma CP plus VarioHeat control panel.

Important notes

– If the power supply to the system has been interrupted, the
time / time switch must be reset.
– If a new or replacement appliance (heater, air conditioning
system) is connected to the bus system, the procedure de-
scribed in "Initial start-up" must be repeated.
Air conditioning systems – shared use of
IR remote control and Truma CP plus VarioHeat
control panel
– Even after connecting the Truma CP plus VarioHeat control
panel, the IR remote control is available for controlling the
air conditioning system. The Truma CP plus VarioHeat con-
trol panel recognises all settings that are made using the
IR remote control on the air conditioning system. The IR re-
mote control only transmits the settings that are shown in
its display (no bidirectional communication).
– Only the time switch of the Truma CP plus VarioHeat control
panel may be used to clearly define the start and end time
of a required period.

Display and control elements

6
7
9
Figure 2
1 = Display
2 = Status bar
3 = Menu bar (upper)
4 = Menu bar (lower)
5 = 230 V mains supply indicator (power)
6 = Time switch display
7 = Settings / Values

8 = Rotary push button

9 = Back button

The menus can be selected in lines (3 + 4) and settings can be
made using the rotary push button (8). The display (1) has an
illuminated background. The Back button (9) can be used to
return from a menu.
20
Rotary push button
Setpoints and paramters can be selected and modified using
the rotary push button (8) and saved by tapping on it. Selected
menu items flash.
+
Rotate clockwise
Figure 3
-
Rotate anticlockwise
Figure 4
Tapping
Figure 5
Long press
Back button
Pressing the Back button (9) returns you from a menu and
discards settings. This means that the previous values are
retained.

Initial start-up

In order to perform the initial start-up, the following steps are
required:
– Switch on power supply.
12 V direct voltage for the Truma CP plus VarioHeat and
Truma VarioHeat control panel, or the 230 V mains voltage
for the air conditioning systems.
1
– Start the search of the appliances under the menu item
"Service menu" –> "RESET" –> "PR SET".
2
After confirmation, the Truma CP plus VarioHeat control panel
3
initialises itself. "INIT .." appears on the display while this is in
progress. The devices that have been found are stored in the
control panel.
5
4

Start-up

Start / Stand-by screen
After connecting the Truma CP plus VarioHeat control panel
8
to the power supply, a start screen is displayed after a few
seconds.
Figure 6
– The display changes between the time and the set
room temperature.
– Special displays on command via IR remote control
of the air conditioning system or CI-BUS (see "Special
displays" on page 24).
– After a repair / retrofit, the procedure described under
"Initial start-up" must be repeated.
– Menu is run through from left to right.
– Increase values (+).
– Menu is run through from right to left.
– Decrease values (-).
– Accept (save) a selected value.
– Select a menu item, switch to setting
level.
– Main switch function ON / OFF.

Quicklinks ausblenden: